141 KB – 6 Pages
PAGE – 1 ============
Cool Gel® Safety Data Sheet according to Regulation (EC) No. 453 /2010 Date of issue : 03/11/1998 Revision date : 18/12/2014 Supersedes : 26/02/2013 Version : 3.0 18/12/2014 EN ( English ) SDS Ref. : LACO1412012 1 / 6 SECTION 1 : Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Product form : Mixture Product name. : Cool Gel ® 1.2. Relevant identified uses of the substance or mixture and uses advised against 1.2.1. Relevan t identified uses Main use category : Industrial use,Professional use Use of the substance/mixture : Heat – absorbing compound 1.2.2. Uses advised against No additional information available 1.3. Details of the supplier of the safety data sheet LA – CO Ind ustries Europe S.A.S. Parc Industriel de la Plaine de – Allée des Combes. 01150.BLYES.France. Phone: +33 (0)4 74 46 23 23 Fax: +33 (0)4 74 46 23 29 E – mail: info@eu.laco.com Web: http://www.markal.com 1.4. Emergency telephone number Emergency number : 24 – hour emergency: CHEMTREC – U.S. : 1 – 800 – 424 – 9300 International: +1 – 703 – 527 – 3887 EU Member State Officieel adviesorgaan Adres Noodnummer AUSTRIA Vergiftungsinformationszentrale (Poisons Information Centre) Allgemeines Krankenhaus Waehringer Geurtel 1 8 – 20 1090 Wien +43 1 406 43 43 BELARUS The Belarus Republican Poisons Centre Kizhevatova str. 58 220115 Minsk +375 (0)17 201 9158 BELGIUM Centre Anti – Poisons/Antigifcentrum c/o Hôpital Central de la Base – Reine Astrid Rue Bruyn 1 B – 1120 Bruxelles/Bruss el +32 70 245 245 BULGARIA National Clinical Toxicology Centre, Emergency Medical Institute “Pirogov” 21 Totleben Boulevard 1606 SOFIA +359 2 9154 409 CROATIA Poisons Control Centre Institute of Medical Research & Occupational Health K saverska Cesta 2 P.O. Box 291 HR – 10000 Zagreb +385 1 234 8342 CZECH REPUBLIC Clinic For Occupational Medicine, 1st Medical Faculty, Charles University 120 00 Praha 2 +42 2 2491 9293 +42 2 2491 5402 DENMARK Giftlinjen Bispebjerg Hospital Bispebjerg Bakke 23, 60, 1 DK – 2400 København NV +45 82 12 12 12 +45 35 31 55 55 ESTONIA Mürgistusteabekeskus Gonsiori 29 15027 Tallinn +372 626 93 90 FINLAND Myrkytystietokeskus P.O.B 340 (Haartmaninkatu 4) HUS SF – 00029 Helsinki +358 9 471 977 FRANCE ORFILA +33 1 45 42 59 59 GERMANY Berliner Betrieb für Zentrale Gesundheitliche Aufgaben Oranienburger Strasse 285 13437 Berlin +49 30 19240 GERMANY Informations und Beratungszentrum für Vergiftungsfälle Kirrberger Straße , Gebäude 9 D – 66421 Homburg/Saar +49 6841 19240 GERMANY Beratungstelle bei Vergiftungen, Klinische Toxikologie und Beratungsstelle bei Vergiftungen Langenbeckstrasse 1 55131 Mainz +49 6131 19240 GREECE Poisons Information Centre 11527 Athens +30 10 779 3777 HUNGARY Országos Kémiai Biztonsági Intézet (National Institute of Chemical Safety) Egészségügyi Toxikológiai Tájékoztató Szolgálat (Health Toxicological Information Service) 1437 Budapest PO Box 839 1097 Budapest, Nagyvárad tér 2 +36 80 20 11 99 ICE LAND Eitrunarmiðstöðin Eitrunarmiðstöðin 108 Reykjavik +354 543 22 22 IRELAND National Poisons Information Centre Beaumont Hospital PO Box 1297 Beaumont Road 9 Dublin +353 1 809 2166 LATVIA ntrs 2 Hipocrate Street LV 1038 Riga +371 67 04 24 73
PAGE – 2 ============
Cool Gel® Safety Data Sheet according to Regulation (EC) No. 45 3 /2010 18/12/2014 EN ( English ) SDS Ref. : LACO1412012 2 / 6 LITHUANIA Siltnamiu 29 2043 Vilnius +370 5 236 20 52/+370 687 53 378 MALTA Medicines & Poisons Info Office Mater Dei Hospital, Msida MSD 2090 Malta 2545 0000 NETHERLANDS Nationaal Vergiftigingen Informatie Centrum National Institute for Public Health and the Environment, NB this service is only available to health professionals Huispostnummer B.00.118, PO Box 85500 3508 GA Utrecht +31 30 274 88 88 PORTUG AL Centro de Informação Antivenenos Instituto Nacional de Emergência Médica (INEM) Rua Almirante Barroso, 36 1000 – 013 Lisboa 808 250 143 (for use only in Portugal), +351 21 330 3284 ROMANIA Biroul pentru Regulamentul Sanitar International si Informare Tox icologica Str. Dr. Leonte Anastasievici Nr.1 – 3, Sector 5 50463 Bucuresti +40 21 318 36 06 SLOVAKIA University Hospital Bratislava Limbová 5 833 05 Bratislava +421 2 54 77 4 166 SPAIN Servicio de Información Toxico lógica Instituto Nacional de Toxicología, Departamento de Madrid Calle Luis Cabrera 9 E – 28002 Madrid +34 91 562 04 20 SWEDEN Giftinformationscentralen Swedish Poisons Information Centre, Karolinska Hospital Box 60 500 SE – 171 76 Stockholm +46 8 33 12 31 (I nternational) 112 (National) SWITZERLAND Centre Suisse d’Information Toxicologique Freiestrasse 16 Postfach CH – 8028 Zurich +41 44 251 51 51 (International) 145 (National) SECTION 2 : Hazards identification 2.1. Classification of the substance or mixture Classification according to Regulation (EC ) No. 1272/2008 [CLP] Show CLP information + DPD classification in section 2.1 Not classified Classification according to Directive 67/ 548/EEC or 1999/45/EC Not classified Adverse physicochemical, human health and environmental effects No additional information available 2.2. Label elements Labelling according to Regulation (EC ) No. 1272/2008 [CLP] No labelling applicable 2.3. Other hazards This substance/mixture does not meet the PBT criteria of REACH, anne x XIII. This substance/mixture does not meet the vPvB criteria of REACH, annex XIII. SECTION 3 : Composition/information on ingredients 3.1. Substances Not applicable 3.2. Mixture This mixture does not contain any substances to be mentioned according to th e criteria of section 3.2 of REACH annex II SECTION 4 : First aid measures 4.1. Description of first aid measures First – aid measures general : Never give anything by mouth to an unconscious person. If you feel unwell, seek medical advice (show the label w here possible). First – aid measures after inhalation : Assure fresh air breathing. First – aid measures after skin contact : Wash skin with mild soap and water. First – aid measures after eye contact : Rinse eyes with water as a precaution. First – aid measur es after ingestion : Call a POISON CENTER/doctor/physician if you feel unwell. 4.2. Most important symptoms and effects, both acute and delayed Symptoms/injuries : Not expected to present a significant hazard under anticipated conditions of normal use. 4.3. Indication of any immediate medical attention and special treatment needed No special procedures required.
PAGE – 3 ============
Cool Gel® Safety Data Sheet according to Regulation (EC) No. 45 3 /2010 18/12/2014 EN ( English ) SDS Ref. : LACO1412012 3 / 6 SECTION 5 : Firefighting measures 5.1. Extinguishing media Suitable extinguishing media : Use extinguishing media appropriate for surrounding f ire. Unsuitable extinguishing media : None known. 5.2. Special hazards arising from the substance or mixture Fire hazard : Not flammable. 5.3. Advice for firefighters Firefighting instructions : Do not allow run – off from fire fighting to enter drains or water courses. Protection during firefighting : Do not enter fire area without proper protective equipment, including respiratory protection. Fire – resistant protective clothing. Wear a self contained breathing apparatus. EN469. SECTION 6 : Accidental r elease measures 6.1. Personal precautions, protective equipment and emergency procedures General measures : This product is not hazardous. 6.1.1. For non – emergency personnel Emergency procedures : Evacuate unnecessary personnel. 6.1.2. For emergency res ponders Emergency procedures : No additional risk management measures required. 6.2. Environmental precautions Contains no substances known to be hazardous to the environment. 6.3. Methods and material for containment and cleaning up Methods for cleanin g up : Wipe up with absorbent material (for example cloth). 6.4. Reference to other sections Section 13: disposal information. Section 7: safe handling . Section 8: personal protective equipment. SECTION 7 : Handling and storage 7.1. Precautions for safe handling Precautions for safe handling : Does not necessitate any specific/particular technical measures. Hygiene measures : Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. 7.2. Condi tions for safe storage, including any incompatibilities Storage conditions : Store in original container. 7.3. Specific end use(s) Metal Working Fluids. SECTION 8 : Exposure controls/personal protection 8.1. Control parameters No additional information a vailable 8.2. Exposure controls Appropriate engineering controls : Ensure good ventilation of the work station. Personal protective equipment : Avoid all unnecessary exposure. Hand protection : None under normal use. Eye protection : No special eye pro tection equipment recommended under normal conditions of use. Respiratory protection : No special respiratory protection equipment is recommended under normal conditions of use with adequate ventilation. SECTION 9 : Physical and chemical properties 9.1. Information on basic physical and chemical properties Physical state : Liquid Appearance : Gel. Colour : clear. Colorless. Odour : Odourless. Odour threshold : No data available pH : 7 Relative evaporation rate (butylacetate=1) : No data av ailable
PAGE – 4 ============
Cool Gel® Safety Data Sheet according to Regulation (EC) No. 45 3 /2010 18/12/2014 EN ( English ) SDS Ref. : LACO1412012 4 / 6 Melting point : 0 °C Freezing point : No data available Boiling point : 100 Flash point : No data available Self ignition temperature : No data available Decomposition temperature : No data available Flammability (solid, gas) : No data available Vapour pressure : No data available Relative vapour density at 20 °C : No data available Relative density : No data available Solubility : No data available Log Pow : No data available Viscosity, kinematic : No data ava ilable Viscosity, dynamic : No data available Explosive properties : No data available Oxidising properties : No data available Explosive limits : No data available 9.2. Other information VOC content : 0 % SECTION 10 : Stability and reactiv ity 10.1. Reactivity No dangerous reactions known. 10.2. Chemical stability Stable under normal conditions. 10.3. Possibility of hazardous reactions Hazardous polymerization will not occur. 10.4. Conditions to avoid None known. 10.5. Incompatible mate rials Water reactive. 10.6. Hazardous decomposition products No dangerous decomposition products known. SECTION 11 : Toxicological information 11.1. Information on toxicological effects Acute toxicity : Not classified (Based on available data, the classif ication criteria are not met ) Skin corrosion/irritation : Not classified (Based on available data, the classification criteria are not met) Serious eye damage/irritation : Not classified (Based on available data, the classification criteria are not met) Respiratory or skin sensitisation : Not classified (Based on available data, the classification criteria are not met) Germ cell mutagenicity : Not classified (Based on available data, the classification criteria are not met) Carcinogenicity : Not classi fied (Based on available data, the classification criteria are not met) Reproductive toxicity : Not classified (Based on available data, the classification criteria are not met) Specific target organ toxicity (single exposure) : Not classified (Based on available data, the classification criteria are not met ) Specific target organ toxicity (repeated exposure) : Not classified (Based on available data, the classification criteria are not met ) Aspiration hazard : Not classified (Based on available data, t he classification criteria are not met) SECTION 12 : Ecological information 12.1. Toxicity No additional information available 12.2. Persistence and degradability No additional information available 12.3. Bioaccumulative potential No additional inform ation available
PAGE – 5 ============
Cool Gel® Safety Data Sheet according to Regulation (EC) No. 45 3 /2010 18/12/2014 EN ( English ) SDS Ref. : LACO1412012 5 / 6 12.4. Mobility in soil No additional information available 12.5. Results of PBT and vPvB assessment Cool Gel® This substance/mixture does not meet the PBT criteria of REACH, annex XIII. This substance/mixture does not meet the vPvB cri teria of REACH, annex XIII. 12.6. Other adverse effects No additional information available SECTION 13 : Disposal considerations 13.1. Waste treatment methods Waste disposal recommendations : Dispose in a safe manner in accordance with local/national reg ulations. EURLW code : For disposal within the EC, the appropriate code according to the European Waste Catalogue (EWC) should be used. SECTION 14 : Transport information In accordance with ADR / RID / ADNR / IMDG / ICAO / IATA 14.1. UN number Not consid ered a dangerous good for transport regulations 14.2. UN proper shipping name Proper Shipping Name (ADR ) : 14.3. Transport hazard class(es) Not applicable 14.4. Packing group Not applicable 14.5. Environmental hazards Other information : No supplement ary information available. 14.6. Special precautions for user 14.6.1. Overland transport No additional information available 14.6.2. Transport by sea No additional information available 14.6.3. Inland waterway transport Carriage prohibited (ADN) : No 1 4.7. Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code Not applicable SECTION 15 : Regulatory information 15.1. Safety, health and environmental regulations /legislation specific for the substance or mixture 15.1.1. EU – Regulations C ontains no substances with Annex XVII restrictions Cool Gel® is not on the REACH Candidate List Contains no REACH candidate substance Contains no REACH Annex XIV substances. VOC content : 0 % 15.1.2. National regulations All components are listed on the EEC inventory European Inventory of Existing Commercial Chemical Substances (EINECS). All ingredients are listed in the Toxic Substances Control Act (TSCA). All ingredients are listed on the Canadian Domestic Substances List (DSL) or Non – Domestic Subst ances List (NDSL). Germany Water hazard class (WGK) : nwg – non – hazardous to water WGK remark : Classification based on the components in compliance withVerwaltungsvorschrift wassergefährdender Stoffe (VwVwS)
PAGE – 6 ============
Cool Gel® Safety Data Sheet according to Regulation (EC) No. 45 3 /2010 18/12/2014 EN ( English ) SDS Ref. : LACO1412012 6 / 6 15.2. Chemical safety assessment No che mical safety assessment has been carried out SECTION 16 : Other information Indication of changes : Revised format. Data sources : ACGIH 2000. Canadian Centre for Occupational Health and Safety. Accessed at: http://www.ccohs.ca/oshanswers/legisl/whmis_classifi.html . ESIS (European chemincal Substances Information System; accessed at: http://esis.jrc.ec.europa.eu/inde x.php?PGM=cla . European Chemicals Agency (ECHA) Registered Substances list. Accessed at http://echa.europa.eu/. Krister Forsberg and S.Z. Mansdorf, “Quick Selection Guide to Chemical Protective Clothing”, Fifth Edition. National Fire Protection Associa tion; Fire Protection Guide to Hazardous Materials; 10th edition. OSHA 29CFR 1910.1200 Hazard Communication Standard. REGULATION (EC) No 1272/2008 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 16 December 2008 on classification, labelling and packagin g of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006. TSCA Chemical Substance Inventory. Accessed at http://www.epa.gov/oppt/existingchemicals/pubs/tscainventory/howto.html. Abbreviations and acronyms : ACGIH (American Conference of Governement Industrial Hygienists). ATE: Acute Toxicity Estimate. CAS (Chemical Abstracts Service) number. CLP: Classification, Labelling, Packaging. EC50: Environmental Concentration associated with a response by 50% of the test population. GHS: Globally Harmonized System (of Classification and Labeling of Chemicals). LD50: Lethal Dose for 50% of the test population. OSHA: Occupational Safety & Healt h Administration. PBT: Persistent, Bioaccumulative, Toxic. PNEC: Predicted No Effect Level. STEL: Short Term Exposure Limits. TSCA: Toxic Substances Control Act. TWA: Time Weight Average. Other information : None. SDS Prepared by: The Redstone Group, LLC 6397 Emerald Pkwy. Suite 200 Dublin, OH USA 43016 T 614 – 923 – 7472 www.redstonegrp.com LA – CO EU CLP SDS This information is based on our current knowledge and is intended to describe the prod uct for the purposes of health, safety and environmental requirements only. It should not therefore be construed as guaranteeing any specific property of the product.
141 KB – 6 Pages